Audi A4, S4
+ Introduction
+ Controls and receptions of safe operation
+ Current leaving and service
+ The engine
+ Systems of cooling, heating and the air conditioner
+ Power supply systems, release and decrease in toxicity of the fulfilled gases
- Systems of an electric equipment of the engine
+ Ignition and engine management system
+ System of preheat of the diesel engine
+ Diagnostics of systems of electronic control and the diagnostic equipment
- Gymnastics and start systems
The general information
The storage battery - the basic data and acquisition of the new battery
Check and gymnastics of the storage battery
Replacement of the storage battery
Storage of the storage battery
Gymnastics system - the general data and security measures
Check of system of gymnastics
Removal and generator installation
Removal and installation of a regulator of pressure/replacement of brushes
System of start of the engine - the general information and safety measures
Removal and starter installation
Check of system of start of the engine
+ Manual box of a gear change
+ Automatic transmission
+ Coupling, power shafts and differential
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment
|
Removal and installation of a regulator of pressure/replacement of brushes Removal
|
- Remove the generator, address to corresponding section.
|
|
Depending on model regulator removal probably also on the established generator. |
|
- Turn away a nut on connecting plugs.
- Turn out screws and remove a protective cover from the generator.
|
|
Depending on model generators of various executions can be established. |
|
- Turn out screws and take out a regulator aside.
- Replace brushes, for what отпаяйте a rope.
- Check up deterioration of rings, if necessary pierce them and polish (work HUNDRED).
|
|
|
Installation
|
- Insert new brushes () and springs () in щёткодержатель () and solder contacts.
|
|
- To exclude solder hit in a rope at a ration, clamp a rope of a brush flat-nose pliers.
|
|
At hit of solder ropes become rigid and brushes unsuitable for work. |
|
- Establish into place a regulator of pressure and fix it.
- After installation of new brushes check up them on ease of a course.
- Fix on the generator a protective cover.
- Screw nuts on connecting plugs.
- Establish into place the generator, address to Section Removal and generator installation.
|
|
|
home
|