Check of warmed back glass At inclusion of heating of back glass the field with visible lines of wires should be released after a while from a covering or snow.
|
- In the presence of malfunctions check up at first a safety lock in the block of safety locks.
- If the safety lock is perfectly in order, remove facing of back glass and check up reliability of connection of the tip at glass at the left and on the right. If necessary clear of corrosion.
- If heating still does not work, check up the block of management of a comfort electric equipment.
- If heater conductors are torn, it is possible to use a usual current-carrying varnish for repair. For this purpose clear the damaged place a thinner or этиленом.
- Paste over the damaged place from both parties with a gluing tape and put a small brush a current-carrying varnish.
- Dry a paint at temperature nearby +25°С within 24 hours. For this purpose it is possible to apply also hot air. At temperature +150°С the paint dries up within 30 minutes
|
Do not include heating of back glass before the paint completely will not dry up. To clearing of the damaged elements do not apply gasoline or other solvents. |
|
|
|